Current transformer TI-100-02S
search
  • Current transformer TI-100-02S

Current transformer TI-100-02S

TI-100-5-02S, 5902431676616

100/5 transformer. 2,5 VA.
The current transformer is used for proportional change of high current strength to lower values, adapted to the measuring range of control and measuring devices.

Operation
The conductor with the current to be measured passes through the main bore of the transformer (P1/P2), which is equivalent to one winding of the primary winding. The terminals of the secondary winding S1 and S2 are connected to the terminals of the measuring circuit of the control or measuring device.
The ratio of the currents in the two windings is a constant quantity and is called the current ratio: IPn/ISn=N, where IPn is the rated primary current; ISn is the rated secondary current; N is the gear value. From the value of the current flowing through the secondary winding, the value of the current flowing through the primary winding can be determined: ISm*N=IPm, where ISm - measured secondary current; IPm - measured primary current.

Сechу of the device

  • Proportional change of high intensities to low intensities.
  • Adapted to the measurement ranges of control and measuring devices.
  • Transformers calibrated in a laboratory accredited by the Polish Centre for Accreditation.
  • Individual certificate confirming accuracy class.
  • Primary current: 100 A.
  • Nominal secondary current: 5 A.

Caution!
Recommended connection of the secondary by a wire with a diameter of not less than 2.5 mm².
Recommended earthing of terminal S2.
It is forbidden to disconnect the secondary circuit during operation of the transformer (possibility of high voltage resulting in shock to persons or damage to the equipment).



TI-100-5-02S
Type
single-phase
Building
with close core
Transmission lp / ls
100/5
Class
0.2S
Power [VA]
1,5 VA
Frequency
50÷60 Hz
Accuracy class
0.2S
Maximum working voltage
0,66 kV AC
Standard number
PN-EN 61869-1:2009; PN-EN 61869-2:2013-06
Nominal secondary current Is
5 A
Isolation breakdown voltage
3 kV/1 min.
Weight
0,5 kg
Security factor
FS ˂ 5
Napięcie robocze
0,66/0,72 kV
Klasa izolacji
E
Ciągły prąd termiczny
1,2× In
Krótkotrwały prąd cieplny [Ith]
60× In
Prąd dynamiczny [Idyn]
2,5× Ith
Napięcie probiercze
3 kV
Connection S1 / S2
zaciski śrubowe 4 mm²
Opening dimensions P1 / P2 - A1 / A2 / A3xB; C [mm]
32 × 32 mm
Dimensions WxHxD [mm]
75×98×42 mm
Tightening torque
0,5 Nm
Working temperature
-5÷40°C
Mounting position
vertical/horizontal
Assembly
blackboard / busway
Ingress Protection Marking
IP20

Wymiary:

Przekładniki wymiary

Wymiary otworu:

Wymiary otworu w przekładniku klasy 0.2S