RT-821, 5908312595717
Functioning
The power supply to the generator is indicated by the green LED. Until the required ambient temperature is achieved, the contact of the regulator remains in position 2-1 and the heating device is active. Once the set value is achieved, the contact shifts into position 2-8 and the heating or ventilation device is turned off. Any drop in temperature by the hysteresis value will activate the heating device again (contacts 2-1 closed) until the set temperature value is achieved.
RT probe | |
design for | RT-820, RT-821, RT-822 |
temperature sensor | KTY 10-6 |
probe dimensions | Ø5; h=20mm |
sensor silolation | thermoshrinkable shirt |
cable | OMY 2×0,34mm²; l=2,5m |
RT823 probe | |
design for | RT-823 |
temperature sensor | KTY 10-6 |
probe dimensions | Ø8; h=40mm |
sensor silolation | brass muff |
cable | SIHF 2×0,5mm²; l=2,5m heatresist |
Availability date:
Power supply voltage | 230 V AC |
The executive element | relay |
Maximum load current | 16 A |
Contact configuration | 1 × NO/NC |
Separation of the contact | YES |
Temperature regulation range | -4÷5°C |
Hysteresis - adjustable | 0,5÷3°C |
Accuracy of setting | 1°C |
Accuracy of measurement | ±1°C |
Temperature probe | RT/RT2 |
Terminal | pluggable terminal blocks 4,0 mm² |
Tightening torque | 0,5 Nm |
Power consumption | 1,1 W |
Working temperature | -25 ÷ 50 °C |
Dimensions | 2 modules (35 mm) |
Assembly | on rail 35 mm |
Ingress Protection Marking | IP20 |