List of products by brand Automatyka F&F

There are 1041 products.

Showing 373-384 of 1041 item(s)

Active filters

Pulse counter MB-LI-4 Hi

Four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

Power consumption limiters OM-2

Adjustable operating power 200-2000 VA. With a constant return time. On plaster.
Power consumption limiters are devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Soft starter SF-110

Three-phases Soft Starts.
Input voltage 3 x 400 V.
Maximum power 11 Kw.
The SF soft starters are used to perform a safe boot of three-phase asynchronous squirrel-cage motors. Soft starter eliminates a star-delta systems and drastically reduces the current surge that occurs during start-up of even heavily loaded motors (e.g. mills and grinding machines).

SF-150 soft start

Three-phase soft starter.

Input voltage 3 x 400 V
Maximum power 15 kW

The SF soft starters are used to perform a safe boot of three-phase asynchronous squirrel-cage motors. Soft starter eliminates a star-delta systems and drastically reduces the current surge that occurs during start-up of even heavily loaded motors (e.g. mills and grinding machines).

Pulse counter MB-LI-4 Hi

MAX-MB-LI-4HI, 5908312598336
Four-channel with MODBUS RTU output.
The pulse counter is used for counting the AC/DC signals generated by external devices to determine the number of completed work cycles and for exchanging the data via RS-485 port in accordance with the MODBUS RTU protocol.

Power consumption limiters OM-2

OM-2, 5908312592181
Adjustable operating power 200-2000 VA. With a constant return time. On plaster.
Power consumption limiters are devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Soft starter SF-110

SF-110, 5908312597513
Three-phases Soft Starts.
Input voltage 3 x 400 V.
Maximum power 11 Kw.
The SF soft starters are used to perform a safe boot of three-phase asynchronous squirrel-cage motors. Soft starter eliminates a star-delta systems and drastically reduces the current surge that occurs during start-up of even heavily loaded motors (e.g. mills and grinding machines).

SF-150 soft start

SF-150, 5908312597520

Three-phase soft starter.

Input voltage 3 x 400 V
Maximum power 15 kW

The SF soft starters are used to perform a safe boot of three-phase asynchronous squirrel-cage motors. Soft starter eliminates a star-delta systems and drastically reduces the current surge that occurs during start-up of even heavily loaded motors (e.g. mills and grinding machines).