Energy meter LE-03M CT
Remote reading. Three phase. RS-485 port + Modbus RTU.
LE-03M CT is a static (electronic) rated energy which is to serve as an auxiliary meters to measure energy consumption in a three phase half direct system.
Remote reading. Three phase. RS-485 port + Modbus RTU.
LE-03M CT is a static (electronic) rated energy which is to serve as an auxiliary meters to measure energy consumption in a three phase half direct system.
A module with 4 analogue voltage outputs (0–10 V) featuring Modbus RTU communication.
4 independent 0–10 V voltage outputs.
Output value memory.
Communication interface: RS-485.
An analogue current transducer with a 4÷20 mA current output.
Measurement input: 0–5 A AC.
For use with a current transformer having a secondary current of 5 A.
True RMS measurement.
The current transformer must be selected separately.
Single-phase AC/DC voltage converter with Modbus RTU communication.
Measurement input range: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Sampling frequency: 10 Hz.
Communication interface: RS-485.
Three-channel AC/DC voltage transducer with Modbus RTU communication.
3 voltage measurement channels.
Range of each channel: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Communication interface: RS-485.
An analogue voltage transducer with a 4–20 mA current output.
Measurement input: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Maximum output cable length: 300 m.
Single-phase current transducer with Modbus RTU communication.
Measurement input: 0–5 A AC.
For use with a current transformer with a secondary current of 5 A.
True RMS measurement.
Communication interface: RS-485.
The current transformer must be selected separately.
current transducer with MODBUS RTU output.
Three-phase 5 A AC.
For use with current transformers.
The MB-3I-1 current transducer is designed to measure alternating or direct current and to exchange data via an RS-485 port in accordance with the MODBUS RTU protocol.
GSM-SIMply MAX P01 two-channel remote controller, 230 V AC
Remote control via SMS (On/Off/Alarm). 2×IN, 2×OUT.
Simple and convenient remote control via mobile phone. The GSM-SIMply MAX P01controller, with its built-in GSM module, allows for convenient control via text messages from a mobile phone or smartphone. It enables you to easily manage outputs and monitor the operating status of all connected devices in real time.
Remote reading. Three phase. RS-485 port + Modbus RTU.
LE-03M CT is a static (electronic) rated energy which is to serve as an auxiliary meters to measure energy consumption in a three phase half direct system.
A module with 4 analogue voltage outputs (0–10 V) featuring Modbus RTU communication.
4 independent 0–10 V voltage outputs.
Output value memory.
Communication interface: RS-485.
An analogue current transducer with a 4÷20 mA current output.
Measurement input: 0–5 A AC.
For use with a current transformer having a secondary current of 5 A.
True RMS measurement.
The current transformer must be selected separately.
Single-phase AC/DC voltage converter with Modbus RTU communication.
Measurement input range: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Sampling frequency: 10 Hz.
Communication interface: RS-485.
Three-channel AC/DC voltage transducer with Modbus RTU communication.
3 voltage measurement channels.
Range of each channel: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Communication interface: RS-485.
An analogue voltage transducer with a 4–20 mA current output.
Measurement input: 0–285 V AC / 0–400 V DC.
True RMS measurement.
Maximum output cable length: 300 m.
Single-phase current transducer with Modbus RTU communication.
Measurement input: 0–5 A AC.
For use with a current transformer with a secondary current of 5 A.
True RMS measurement.
Communication interface: RS-485.
The current transformer must be selected separately.
current transducer with MODBUS RTU output.
Three-phase 5 A AC.
For use with current transformers.
The MB-3I-1 current transducer is designed to measure alternating or direct current and to exchange data via an RS-485 port in accordance with the MODBUS RTU protocol.
GSM-SIMply MAX P01 two-channel remote controller, 230 V AC
Remote control via SMS (On/Off/Alarm). 2×IN, 2×OUT.
Simple and convenient remote control via mobile phone. The GSM-SIMply MAX P01controller, with its built-in GSM module, allows for convenient control via text messages from a mobile phone or smartphone. It enables you to easily manage outputs and monitor the operating status of all connected devices in real time.