Three-phase asymmetry and sequence monitors CKF-319 True RMS

Three-phase asymmetry and sequence monitors CKF-319 True RMS

CKF-319-TRMS, 5902431672571

Product description

To protect electric motors supplied from a three-phase network in the event of a power failure in at least one phase or voltage unbalance between phases that threatens to destroy the motor and to protect the direction of rotation of the motor in the event of a phase change in front of the sensor.

 The sequence and phase loss sensor is designed to protect an electric motor supplied from a three-phase network in the cases of:
- power failure in at least one phase;
- voltage drop in at least one phase below 150 V;
- voltage increase in at least one phase above 280 V;
- voltage unbalance between phases above the set value;
- incorrect phase sequence.



 

Functioning
The correct supply voltage is indicated by the green LED diode. Voltage drop below 150 V or increase above 280 V on at least one, any phase, or voltage asymmetry above the set value is signaled by the green diode not lighting.
Both of the above anomalies (exceeding the voltage threshold, asymmetry) cause the device relay to turn off and, as a result, disconnect the motor.
In the case of asymmetry, disconnection is carried out with a set delay to avoid accidental shutdowns for temporary disturbances in the network.
In the event of a voltage drop below 150 V or an increase above 280 V, the disconnection is carried out after 1 s. The countdown to switching off is signaled by the flashing green diode.
The relay is switched on again automatically when the correct network parameters return (voltage hysteresis is about 5 V).
If the phase sequence in front of the sensor changes, causing the motor to rotate inadvertently, the sensor will not allow the motor to start (the red LED is on and the relay is off). Reconnection is possible after the correct phase sequence has been returned.
In case of incorrect connection of the input wires (phase in the place of the neutral wire), the LEDs flash in the order red, green indicating a connection error (in this case the output relay will not be turned on).
 

Power supply voltage 3 × 400 V + N
Cooperation with power generators NO
Phase failure / asymmetry monitoring YES
Phase sequence control YES
Contactor contact monitoring NO
The executive element relay
Maximum load current 2 × 8 A
Contact configuration 2 × NO/NC
Separation of the contact YES
Voltage asymmetry 20÷80 V
Voltage hysteresis 5 V
Switch off delay 1÷10 s
Switch on delay 1÷60 s
Power control 2 × LED
Switch off delay when asymmetry and decay 1÷10 s
Switch off delay in the absence of phase 1 s
Terminal pluggable terminal blocks 2,5 mm²
Tightening torque 0,4 Nm
Power consumption 1,6 W
Working temperature -25÷40°C
Dimensions 1 module (18 mm)
Assembly on rail 35 mm
Ingress Protection Marking IP20
TrueRMS TAK