Signal lamp LK-714 130÷260 V AC/DC
Two states. Two LEDs: green, red. Voltage range 130÷260 V AC/DC.
The signal light LK-714 is used for optical signaling circuits or states listed receivers, such as closed - open; work - break, etc.
Two states. Two LEDs: green, red. Voltage range 130÷260 V AC/DC.
The signal light LK-714 is used for optical signaling circuits or states listed receivers, such as closed - open; work - break, etc.
An analogue current transducer with a 4–20 mA current output.
Measurement input: 0–15 A AC / 0–20 A DC.
Direct measurement.
True RMS measurement
Temperature transmitter for thermocouples with Modbus RTU communication.
Supported thermocouple types: K, J, E, N, T, S, R, B.
Hot and cold junction measurement.
4 independent temperature alarms.
Communication interface: RS-485.
An external thermocouple is required for measurement.
4-channel operating time counter with high-voltage counting inputs and Modbus RTU communication.
4 independent counting inputs.
Input voltage range: 160–265 V AC/DC.
Input time filter.
Counter status memory in the event of a power failure.
Light intensity sensor with Modbus RTU communication.
Built-in light intensity sensor.
Continuous measurement.
Averaging of results: 1 to 30 most recent samples.
Communication interface: RS-485.
Surface-mounted, IP65.
ST25-20 25 A modular contactor with a 24 V AC coil and two NO contacts. Version designed for 24 V AC control systems.
ST25-11 25 A modular contactor with a 230 V AC coil, one NO contact and one NC contact.
ST25-30 25 A modular contactor with a 230 V AC coil and three normally open contacts.
ST25-31 25 A modular contactor with a 230 V AC coil and a contact configuration of 3×NO + 1×NC.
ST25-31 25 A modular contactor with a 24 V AC coil, three NO contacts and one NC contact.
Two states. Two LEDs: green, red. Voltage range 130÷260 V AC/DC.
The signal light LK-714 is used for optical signaling circuits or states listed receivers, such as closed - open; work - break, etc.
An analogue current transducer with a 4–20 mA current output.
Measurement input: 0–15 A AC / 0–20 A DC.
Direct measurement.
True RMS measurement
Temperature transmitter for thermocouples with Modbus RTU communication.
Supported thermocouple types: K, J, E, N, T, S, R, B.
Hot and cold junction measurement.
4 independent temperature alarms.
Communication interface: RS-485.
An external thermocouple is required for measurement.
4-channel operating time counter with high-voltage counting inputs and Modbus RTU communication.
4 independent counting inputs.
Input voltage range: 160–265 V AC/DC.
Input time filter.
Counter status memory in the event of a power failure.
Light intensity sensor with Modbus RTU communication.
Built-in light intensity sensor.
Continuous measurement.
Averaging of results: 1 to 30 most recent samples.
Communication interface: RS-485.
Surface-mounted, IP65.
ST25-20 25 A modular contactor with a 24 V AC coil and two NO contacts. Version designed for 24 V AC control systems.
ST25-11 25 A modular contactor with a 230 V AC coil, one NO contact and one NC contact.
ST25-30 25 A modular contactor with a 230 V AC coil and three normally open contacts.
ST25-31 25 A modular contactor with a 230 V AC coil and a contact configuration of 3×NO + 1×NC.
ST25-31 25 A modular contactor with a 24 V AC coil, three NO contacts and one NC contact.