Electronic bistable impulse relay BIS-419-LED 230 V
Sequential. Power supply 230 V AC . Maximum load 2 x 16 A (160 A / 20 ms). On the 35 mm rail. Can be used with backlit buttons.
LK-701R 110 V indicator lamp is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 red
Single-phase.
With open core.
Primary current 100 A
Secondary current 30 mA
For use with Energy 1 or Energy 3 FOX energy consumption monitor.
Current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring devices.
Converter RS-485 <=> USB.
Input voltage: 12-20V DC
Output voltage: 24V DC
Continuous power: 200 W
Frequency: 50/60 Hz
A voltage converter is an electrical device whose task is to provide electricity to devices whose parameters do not allow direct connection to the receiver.
The DRL-12 is a laser sensor designed to control lighting, especially in corridors and staircases.
Precise detection setting from 0.1 to 2 m, direct load up to 50 W / 12 V DC, cooperation with AS-225 controllers, built-in brightness sensor.
Control lamp LK-701R 230 V is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 red
The DRL-12 is a laser sensor designed to control lighting, especially in corridors and staircases.
Precise detection setting from 0.1 to 2 m, direct load up to 50 W / 12 V DC, cooperation with AS-225 controllers, built-in brightness sensor.
LK-701Y 24 V indicator lamp is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 yellow
LK-701R 110 V indicator lamp is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 red
Single-phase.
With open core.
Primary current 100 A
Secondary current 30 mA
For use with Energy 1 or Energy 3 FOX energy consumption monitor.
Current transformer is used to proportionally change large current intensities to lower values, adapted to the measuring ranges of control and measuring devices.
Input voltage: 12-20V DC
Output voltage: 24V DC
Continuous power: 200 W
Frequency: 50/60 Hz
A voltage converter is an electrical device whose task is to provide electricity to devices whose parameters do not allow direct connection to the receiver.
The DRL-12 is a laser sensor designed to control lighting, especially in corridors and staircases.
Precise detection setting from 0.1 to 2 m, direct load up to 50 W / 12 V DC, cooperation with AS-225 controllers, built-in brightness sensor.
Control lamp LK-701R 230 V is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 red
The DRL-12 is a laser sensor designed to control lighting, especially in corridors and staircases.
Precise detection setting from 0.1 to 2 m, direct load up to 50 W / 12 V DC, cooperation with AS-225 controllers, built-in brightness sensor.
LK-701Y 24 V indicator lamp is used to visually indicate the presence of voltage in an electrical circuit.
LED color x 1 yellow