Electricity consumption meter, 3-phase, resetable LE-03-FPV-RST
search
  • Electricity consumption meter, 3-phase, resetable LE-03-FPV-RST
  • Electricity consumption meter, 3-phase, resetable LE-03-FPV-RST
  • Electricity consumption meter, 3-phase, resetable LE-03-FPV-RST

Electricity consumption meter, 3-phase, resetable LE-03-FPV-RST

LE-03-FPV-RST, 5902431676128

The LE-03-FPV-RST meter is an electronic, legalised (MID declaration), 3-phase, 4-wire electricity meter for direct metering.

The meter is capable of measuring both active energy consumed and energy given up, making it ideal for monitoring energy production and consumption in photovoltaic installations.
The LE-03-FPV-RST is also equipped with an additional erasable energy meter, facilitating direct observation of the increase in energy since the previous meter reset, and an illuminated reading field.

MID Directive 2014/32/EU
Certificate 0120/SGS0670

Under the influence of the flowing current and applied voltage, the meter precisely measures energy and active power. The current data is displayed on a 7-character LCD. Energy increments (separately for imported and exported energy) are additionally indicated by blinking LEDs on the front of the unit. The meter is also equipped with a pulse output to indicate a change in total energy (total energy = imported energy + exported energy).



LE-03-FPV-RST
Type
three-phase
Measurement
Direct
Installation
3-phase, 4-wire
The minimum measured current
0,003 A
Base current
10:00 AM
Reference voltage
3×230/400 V
Maximum current
3×100 A
Nominal frequency
50 Hz
Insulation protection class
II class
Counter's own consumption
10 VA; 2 W
Scope of indication of the abacus
8 cyfr
Compatibility
MID
Communication protocol
NONE
Prędkość transmisji
1200, 2400, 4800, 9600 bps
Parzystość
EVEN
Stop bits
1
LCD backlight
YES
Reading signaling
2 x LED
Pulse output SO + SO-
open collector
Connection voltage SO + SO-
max. 30 V DC
Connection current SO + SO-
max. 27 mA
Accuracy class
B
overload
30×lmax/10 ms
Insulation
4 kV/1 min.; 6 kV/1 μs
Voltage measured L-N
100÷289 V AC
Voltage measured L-L
173÷500 V AC
Terminal
pluggable terminal blocks 25 mm²
Working temperature
-25 ÷ 50 °C
Dimensions
76×100×65 mm (4,5 modułu DIN)
Assembly
on rail 35 mm
Ingress Protection Marking
IP51
Measuring system
3-phase 4-wire
2-way energy measurement
TAK

Licznik dwukierunkowy do fotowoltaiki

Produkt Licznik
1-fazowy
Licznik
3-fazowy
Wskaźnik
1-fazowy
Wskaźnik
3-fazowy
MID Pomiar
pośredni
Pomiar
półpośredni
2-kierunkowy Pomiar dodatkowych parametrów Komunikacja Podświetlenie
liczydła
Kasowanie
Energia czynna pobrana Energia czynna oddana Energia bierna Energia bierna pobrana Energia bierna oddana Moc czynna, bierna, pozorna Zapotrzebowanie na moc Napięcie Prąd Częstotliwość Współczynnik mocy Ethernet Modbus M-Bus
LE-01
LE-01d
LE-01DC bocznik
LE-01M
LE-01MB
LE-01MQ
LE-01MR
LE-01MW
LE-01R
LE-02d
LE-02d CT
LE-03
LE-03d
LE-03d CT200
LE-03d CT400
LE-03ETH
LE-03ETH-CT
LE-03 FPV-RST
LE-03M
LE-03M CT
LE-03MB
LE-03MB CT
LE-03MP
LE-03MQ
LE-03MQ CT
LE-03MW
LE-03MW CT
LE-04d
LE-05d
NEL-1-30
NEL-1-60
NEL-3-100
WZE-1
WZE-1-RST
WZE-3
WZE-3-RST