There are 668 products.

Showing 121-132 of 668 item(s)

Active filters

Power consumption limiters OM-632

OM-632, 5908312591719
Adjustable operating power 200-2000 VA. For circuit with converters.
Power consumption limiters are devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Power consumption limiters OM-611

OM-611, 5908312596165
With adjustable actuation and return time. For cooperation with a current transformer.
Power consumption limiters OM-611 is devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Priority relays PR-602

PR-602, 5908312595939
Fixing to the base. Adjustment range 2 ÷ 15 A.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-612

PR-612, 5908312595908

On rail TH-35. Adjustment range 2 ÷ 15 A.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-603

PR-603, 5908312595946
Fixing to the base. Adjustment range 2 ÷ 15 A. With through passage for the receiver\'s current cable.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-613

PR-613, 5908312595915
On rail TH-35. Adjustment range 2 ÷ 15 A. With through passage for the receiver\'s current cable.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-614

PR-614, 5908312595922
On rail TH-35. For cooperation with a current transformer.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Fuse module BZ-1

BZ-1, 5908312592211
One-socket.
Fuse mreceiver modules serve as a security device for electric receivers against current increase over the nominal current value for the secured.

Fuse module BZ-2

BZ-2, 5908312596240
Two-sockets.
Fuse mreceiver modules serve as a security device for electric receivers against current increase over the nominal current value for the secured.

Fuse module BZ-3

BZ-3, 5908312596257

Three-sockets.
Fuse mreceiver modules serve as a security device for electric receivers against current increase over the nominal current value for the secured.

Fuse module BZ-4

BZ-4, 5908312596264
Four-sockets.
Fuse receiver modules serve as a security device for electric receivers against current increase over the nominal current value for the secured.

Power consumption limiters OM-632

OM-632, 5908312591719
Adjustable operating power 200-2000 VA. For circuit with converters.
Power consumption limiters are devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Power consumption limiters OM-611

OM-611, 5908312596165
With adjustable actuation and return time. For cooperation with a current transformer.
Power consumption limiters OM-611 is devised for the automatic disconnection of power from the circuit of single-phase wiring systems once the rated power consumption of the receivers incorporated into the system is exceeded.

Priority relays PR-603

PR-603, 5908312595946
Fixing to the base. Adjustment range 2 ÷ 15 A. With through passage for the receiver\'s current cable.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-613

PR-613, 5908312595915
On rail TH-35. Adjustment range 2 ÷ 15 A. With through passage for the receiver\'s current cable.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.

Priority relays PR-614

PR-614, 5908312595922
On rail TH-35. For cooperation with a current transformer.
Priority relays are designed to control the value of current drawn by electric receivers and their control units in cases where their simultaneous work could result in circuit overload or current overload protection activation.