Electronic bistable impulse relay BIS-412Mi 230 V

Electronic bistable impulse relay BIS-412Mi 230 V

BIS-412Mi 230 V

BIS-412 electronic bi-stable pulse relay is designed for operation in a group configuration.
Relay version "i" is to pin adapted to cooperate with the receivers with high starting current, such as LED fluorescent lamps, ESL fluorescent lamps, electronic transformers, discharge lamps, etc.
Power supply 230 V AC. Maximum load 16 A (160 A/20 ms). On rail TH-35. With the memory of the contact position. Can be used with backlit buttons.
A single relay enables the activation and deactivation of the receiver controlled after each current pulse triggered by pushing a local control momentary push-button (bell-push). The group configuration enables the deactivation or activation of all receivers connected to individual relays by means of the central control push-buttons.

Functioning:
Local control
The receiver is activated after a current pulse that is triggered by pushing one optional momentary push-button  belonging to the local control group. The contact of the relay is switched to the 7-10 position. After a next current pulse, the receiver will be deactivated (the contact of the relay returns to the 7-12 position). 
Central control
DEACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be deactivated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-12 position.
ACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be activated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-10 position. 
 
 

Attention!
The BIS-412 230V is compatible with bell pushes equipped with fluorescent lamps.          

Power supply voltage165├Ě265 V AC
Local controlYES
Maximum AC-1 load current16 A (160 A/20 ms)
The executive elementrelay
Contact configuration1 ├Ś NO
Separation of the contactYES
Resistance to shock currentsYES
Number of channels1
functionalitygroup (hotel)
Delay of operation0,1 ├Ě 0,2 s
Control pulse currentless than 5 mA
Cooperation with illuminated buttonsYES
Status memory after power failureYES
Activate on timeNO
Dedicated central control inputsYES
Radio controlNO
terminalscrew terminals 2,5 mm┬▓
Tightening torque0,4 Nm
Power consumption0,7 W
Working temperature-25 ├Ě 50 ┬░C
dimensions1 module (18 mm)
Assemblyon rail 35 mm
Level of securityIP20
Przyciski pod┼Ťwietlane
Z uwagi na niskie napi─Öcie zasilania nie nale┼╝y stosowa─ç przycisków pod┼Ťwietlanych.

Maksymalny pr─ůd obci─ů┼╝enia
Pr─ůd styku podany w danych technicznych jest warto┼Ťci─ů maksymaln─ů i mo┼╝e podlega─ç ograniczeniom – wi─Öcej informacji. Je┼Ťli z przedstawionych informacji wynika, ┼╝e przeka┼║nik w urz─ůdzeniu jest niewystarczaj─ůcy zaleca si─Ö stosowa─ç zewn─Ötrzny element prze┼é─ůczaj─ůcy (np. stycznik) przystosowany do prze┼é─ůczania du┼╝ych pr─ůdów udarowych.


Pami─Ö─ç stanu
Wersja przeka┼║nika z liter─ů "M" posiada pami─Ö─ç pozycji styku, tzn. po za┼é─ůczeniu zasilania zostanie przywrócony stan przeka┼║nika jaki by┼é w momencie wy┼é─ůczenia zasilania..

Odporno┼Ť─ç na pr─ůdy udarowe
W urz─ůdzeniu zastosowany zosta┼é przeka┼║nik typu "inrush" charakteryzuj─ůcy si─Ö du┼╝─ů wytrzyma┼éo┼Ťci─ů na krótkotrwa┼ée pr─ůdy udarowe powstaj─ůce np. w momencie za┼é─ůczenia lamp LED, ┼Ťwietlówek ESL, tranformatorów elektronicznych, lamp wy┼éadowczych itp.