BIS-412M-LED, 5902431671505
Functioning:
Local control
The receiver is activated after a current pulse that is triggered by pushing one optional momentary push-button belonging to the local control group. The contact of the relay is switched to the 7-10 position. After a next current pulse, the receiver will be deactivated (the contact of the relay returns to the 7-12 position).
Central control
DEACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be deactivated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-12 position.
ACTIVATE ALL - after a current pulse triggered by pushing the momentary push-button , all receivers will be activated (regardless of their status, i.e. deactivation or activation) that are controlled separately by individual relays. The contact in each relay will be switched to the 7-10 position.
Attention!
The BIS-412 230V is compatible with bell pushes equipped with fluorescent lamps.
Availability date:
Power supply voltage | 165÷265 V AC |
Local control | YES |
Maximum AC-1 load current | 16 A (120 A/20 ms) |
The executive element | relay |
Contact configuration | 1 × NO |
Separation of the contact | YES |
Resistance to shock currents | YES |
Number of channels | 1 |
functionality | group (hotel) |
Delay of operation | 0,1 ÷ 0,2 s |
Control pulse current | less than 5 mA |
Cooperation with illuminated buttons | YES |
Status memory after power failure | YES |
Activate on time | NO |
Dedicated central control inputs | YES |
Radio control | NO |
Terminal | pluggable terminal blocks 2,5 mm² |
Tightening torque | 0,4 Nm |
Power consumption | 0,7 W |
Working temperature | -25 ÷ 50 °C |
Dimensions | 1 module (18 mm) |
Assembly | on rail 35 mm |
Ingress Protection Marking | IP20 |