Electronic bistable impulse relay BIS-419-LED 24 V

Electronic bistable impulse relay BIS-419-LED 24 V

BIS-419-LED-24V, 5908312599210

Product description

The electronic bistable relay enables switching on the lighting or other device from several different points by means of parallel connected control buttons.
Sequential. Power supply 24V AC . Maximum load 2 x 16 A (160 A / 20 ms). On the 35 mm rail.

Electronic bistable pulse relay enables switching on or off the lighting or other device from several different points by means of parallel connected, momentary (bell) control switches.

The BIS-419 relay has two switching sections and enables two circuits (branches) of lighting or other receivers to be connected according to the selected sequence from several different points.
 

Functioning
Power supply of the relay is signaled by the green LED. The sequential relay has two separate outputs R1 and R2. The contact status (closed / open) is forced sequentially according to the given program. Switching the contacts into the next state follows the next pulse of the control button. Switching on contact R1 and R2 is signaled by lighting of the corresponding red LEDs R1 and R2. After a power failure, the contact status is reset. After restarting the supply voltage, the relay starts operation from sequence No. 0.
 

Work functions

Function A


 
   

Subsequent presses of the button repeat sequence 0-3.
 

Function B

* Repeatedly pressing the button in less than 5 seconds, repeats sequences 1-3.
* The next pressing of the button after a time longer than 5 s, disconnects both contacts (sequence 0).
* Long press of the button - in any sequence - disconnects both contacts (sequence 0).
* After switching off both relays, pressing the button again restores the state before the shutdown (state memory). It does not apply to the case of power failure of the relay.
 

Function C

Subsequent presses of the button repeat sequence 0-3.
 

Function D


 

* Repeatedly pressing the button in less than 5 seconds, repeats sequences 1-3.
* The next pressing of the button after a time longer than 5 s, disconnects both contacts (sequence 0).
* Long press of the button - in any sequence - disconnects both contacts (sequence 0).
* After switching off both relays, pressing the button again restores the state before the shutdown (state memory). It does not apply to the case of power failure of the relay.
  

Power supply voltage9÷30 V AC/DC
Local controlYES
Maximum AC-1 load current2 x16 A (120 A/20 ms)
The executive elementrelay
Contact configuration2 × NO
Separation of the contactYES
Resistance to shock currentsYES
Number of channels2
functionalitysequential
Delay of operation0,1 ÷ 0,2 s
Control pulse currentless than 1 mA
Cooperation with illuminated buttonsYES
Tightening torque0,4 Nm
Working temperature-25 ÷ 50 °C
Dimensions1 module (18 mm)
Assemblyon rail 35 mm
Ingress Protection MarkingIP20
Przyciski podświetlane
Z uwagi na niskie napiÄ™cie zasilania nie należy stosować przycisków podÅ›wietlanych.

Maksymalny prąd obciążenia
PrÄ…d styku podany w danych technicznych jest wartoÅ›ciÄ… maksymalnÄ… i może podlegać ograniczeniom – wiÄ™cej informacji. JeÅ›li z przedstawionych informacji wynika, że przekaźnik w urzÄ…dzeniu jest niewystarczajÄ…cy zaleca siÄ™ stosować zewnÄ™trzny element przeÅ‚Ä…czajÄ…cy (np. stycznik) przystosowany do przeÅ‚Ä…czania dużych prÄ…dów udarowych.


Pamięć stanu
Przekaźnik nie posiada "pamięci" pozycji styku. Oznacza to, że po załączeniu zasilania styk przekaźnika zawsze pozostanie w stanie wyłączonym.

Odporność na prądy udarowe
W urzÄ…dzeniu zastosowany zostaÅ‚ przekaźnik typu "inrush" charakteryzujÄ…cy siÄ™ dużą wytrzymaÅ‚oÅ›ciÄ… na krótkotrwaÅ‚e prÄ…dy udarowe powstajÄ…ce np. w momencie zaÅ‚Ä…czenia lamp LED, Å›wietlówek ESL, tranformatorów elektronicznych, lamp wyÅ‚adowczych itp.